Thermocouples

 

Fe-CuNi type L as per DIN 43710

operating temperature:   -200°C up to +900°C
 

  Limiting deviation and tolerances
class 1 - -
  - -
class 2 0 °C up to +900 °C 0 °C up to +900 °C
  ± 3,0 °C ± 0,75 %
class 3 - -
  - -

 

Color code compensating wire
jacket: blue
positive
leg:
red
negative
leg:
blue
 
Fe-CuNi type J as per DIN EN 60584

operating temperature:   -40 °C up to +750 °C
 

  Limiting deviation and tolerances
class 1 -40 °C up to +750 °C -40 °C up to +750 °C
  ± 1,5 °C ± 0,4 %
class 2 -40 °C up to +750 °C -40 °C up to +750 °C
  ± 2,5 °C ± 0,75 %
class 3 - -
  - -

 

Color code compensating wire
jacket: black
positive
leg:
black
negative
leg:
white
NiCr-Ni Typ K as per DIN EN 60584

operating temperature:   -200 °C up to +1200 °C
 

  Limiting deviation and tolerances
class 1 -40 °C up to +1000 °C -40 °C up to +1000 °C
  ± 1,5 °C ± 0,4 %
class 2 -40 °C up to +1200 °C -40 °C up to +1200 °C
  ± 2,5 °C ± 0,75 %
class 3 -200 °C up to +40 °C -200 °C up to +40 °C
  ± 2,5 °C ± 1,5 %

 

Color code compensating wire
jacket: green
positive
leg:
green
negative
leg:
white

 

 

Resistance Sensors

 

Pt100 - Resistance table and basic values of the measuring resistance (Accuracy classes as per DIN EN 60751)
wire-wound resistance
sheet resistance
 
-50 up to +250 0 up to +150 ± (0,1 + 0,0017 [t])
-100 up to +450 -30 up to +300 ± (0,15 + 0,002 [t])
-196 up to +600 -50 up to +500 ± (0,3 + 0,005 [t])
-196 up to +600 -50 up to +600 ± (0,6 + 0,01 [t])

 

Color code compensating wire
jacket: red
positive
leg:
red
negative
leg:
white

Any
questions?

Find your contact person in one of our locations!

Contact